Electronic total pressure sensor Measurement of the velocity distribution in the intake tube on HM 240 Features - electronic measurement of static and dynamic pressure - record pressure distribution in the wake of a cylinder in conjunction with HM 240.04 - accessory for HM 240 Learning objectives/experiments - in conjunction with HM 240 -- measurement of the total pressure and the static pressure in HM 240's intake pipe -- recording pressure distribution over the cross section -- determining velocity distribution over the cross section - in conjunction with HM 240.04 -- measurement of the total pressure in the wake of a cylinder -- determine drag coefficient from the pressure distribution in the wake of a cylinder -- demonstrate wake depression Specification [1] electronic total pressure sensor for measurement of static and dynamic pressure [2] accessory for HM 240 [3] vertical adjustment of the Pitot tube [4] electronic detection of the position [5] in conjunction with HM 240.04 measurement of the total pressure in the wake of a cylinder [6] display and analysis of the measured values using the software in HM 240 Technical data Pitot tube - outer diameter: 0,71mm - inner diameter: 0,41mm - vertical adjustment: 0...130mm LxWxH: 120x75x350mm (retracted) Weight: approx. 1kg