The HL 530 is used to illustrate the functioning of a gas combination boiler. The main components of the gas boiler are clearly arranged on a panel to allow better understanding. A process schematic also illustrates the function. The HL 530 allows demonstration of a heating circuit and representation of domestic water heating. A plate heat exchanger is used to simulate a radiator. Cold water is fed through the heat exchanger as a heating load. A viewing window allows observation of the gas flame in the burner. Built-in thermometers and flow meters allow the recording of measured values to determine the power and efficiency. The unit is operated with liquid gas (propane) and is therefore independent of any pre-installed natural gas lines.
HL 530 Training panel function of gas heater

The illustration shows a similar unit
Features
- clearly arranged components of a typical combination boiler
- separate circuits for room heating and domestic water heating
- viewing window for flame observation
- additional instrumentation for energy balances
Learning objectives/experiments
- familiarisation with the functioning of a combination boiler
- understanding of a heating circuit
- domestic water heating
- measurement of gas pressures on a gas boiler
- determination of power and efficiency
Scope of delivery
1 trainer
1 manual
Description
Technical details
Specification
- familiarisation with a typical combination boiler
- main components clearly mounted on panel
- burner with viewing window for observation of flame
- plate heat exchanger simulates radiator, cold water used as heating load
- additional instrumentation for energy balances: thermometers, flow meters, manometers
- operation with propane gas
Technical data
Gas boiler
- nominal heating capacity range: 8.9…18kW
- standard utilisation rate at nominal load: 93%
- feed flow temperature: 82…87°C
- hot water temperature: 30…65°C
- permissible excess operating pressure
- heater: 3bar
- hot water: 10bar
- exhaust gas temperature: 90…125°C
Expansion vessel
- capacity: 2L
- admission pressure: 1,5bar
230V, 50Hz, 1 phase
Dimensions and weight
LxWxH: 1650x700x1900mm
Weight: approx. 115kg
Required for operation
propane gas: 1,72kg/h, 50mbar
water connection, drain
ventilation, exhaust gas routing
Order number: 065.53000
Alternative products
Heating boiler with viewing window for observing the flame
Learning objectives/experiments
- layout and operating behaviour of an oil burner
- operation of a heating boiler with an oil burner
- effect of burner setting on combustion and on the flame
- temperature measurements in different areas of the combustion chamber
- oil pressure measurements on the burner with observation of the effects of changes on the flame
….
Heating boiler with an oil burner; hot water generator for other trainers from the HL series
Learning objectives/experiments
- function of an oil burner
- operation of a heating boiler with an oil burner
- burner adjustment during operation
- temperature measurements in different areas of the combustion chamber
- calculation of the heating capacity of a heating boiler
….
Design and operating behaviour of a heating boiler with hot water storage
Learning objectives/experiments
- design and operating behaviour of a heating boiler
- comparison of burners (3 different burners available as accessories)
- changes in settings during operation with observation of the effects on the flame pattern
- temperature measurements in different areas of the combustion chamber
- oil pressure measurements on the burner with observation of the effect on the flame pattern
….
Methods of gas burner adjustment; simulation of twelve faults
Learning objectives/experiments
- gas burner adjustment by volumetric method
- nozzle pressure method for gas burner adjustment
- fault finding